You are currently in:home > Products > Insulator
 
Return
 
12、Composite interphase spacer
Browse the number:4431   Release time:2014-04-29     [Return

Summary.

High voltage composite insulators and AC gapless metal oxide surge arrester is a national "seven five" major technology and equipment research project and the "eight five" key promotion products.

China. Yuan Electric Power Technology Co., Ltd. is a professional production, research and development, sales of electric power fittings, composite insulator, composite insulator, composite interphase spacer polymeric housed metal oxide surge arrester, falling type fuse, high voltage isolating switch, lightning protection composite insulator and a high voltage lightning protection device for high voltage products as a whole the modern high-tech enterprises. Can batch production of products of all kinds of 500kV and below voltage levels. The qualified test all products by the national insulator arrester quality supervision and inspection center and the Ministry of electric power industry electrical equipment testing center, crimp type connection form a stable and reliable quality, aluminum, an equalizing ring is the domestic original closed, to provide assurance for the safe operation of electric power; in production conscientiously follow the international standard ISO9001, and successfully passed the national authority of the organization's quality management system and product quality system certification


At present, the company produces the product operation in the country more than 30 provinces, the city, the running time of the earliest hanging network has reached 5 years, and the products are exported to South America, Africa, Middle East, Southeast Asia and other countries and regions, exports about 2000000 U. s.dollars years.
The company invested hundreds of million yuan for technical improvement and modification of the laboratory, 600kV high voltage frequency test chamber has been put into use, 10kV ~ 500kV, 70kN ~ 300kN voltage grade, various tensile load altogether more than 30 varieties of one-time through the national quality supervision and inspection in the insulator arrester test (Test Center certification center of Xi'an High Voltage Electrical Apparatus Research Institute) the test is carried out, some new technology,The company invested hundreds of million yuan for technical improvement and modification of the laboratory, 600kV high voltage frequency test chamber has been put into use, 10kV ~ 500kV, 70kN ~ 300kN voltage grade, various tensile load altogether more than 30 varieties of one-time through the national quality supervision and inspection in the insulator arrester test (Test Center certification center of Xi'an High Voltage Electrical Apparatus Research Institute) the test is carried out, some new technology,
A, product use:

Composite interphase spacer is a device for holding wire distance, inhibition of conductor galloping. Mainly by the composite interphase interval insulator, ear groove clamp, damping pad and other components. The composite interphase interval insulator not only plays the interphase interval and insulation, electrical isolation, and plays a role of interphase mechanical load transfer. Applicable to high voltage transmission lines, used especially in polluted areas, can effectively prevent the pollution flashover accident, without the need for manual cleaning, to avoid zero maintenance, can effectively prevent short circuit caused by conductor line and etc., is the current international and European and American countries and regions are widely used in high quality products.Because the line installed in different ways and different climatic conditions will lead to phase conductors do different sports, so the whole device stress is complex, so I generally require the user to provide detailed technical conditions to adjust the product design, and strive to manufacture products, and require the installation of a standardized and professional.


Two, the basic requirement of line:
1, wire specifications in the scope of application.
2, conductor interphase sag relative error less than 100mm.
3, usually installation will require workers to climb the ladder hanging on the wire, wire and requirements of suspension point should meet the strength requirements.
4, hanging ladder on the wire, the multi loop and below the cross should meet the safety rules (circuit).
5, abnormal shall timely handle.
Three, the main technical parameters:
 
The product model

Rated voltage
(kV)
The height of the structure
(mm)
Full wave lightning impulse withstand voltage dry
(kV)
Power frequency withstand voltage (effective value) not less than kV
Remarks
湿
FXGB-660D
66
2500
410
215
185
D- single wire
S- double wire
 
FXGB-66S
66
2600
410
215
185
FXGB-110D
110
3000
550
265
230
FXGB-110S
110
3000
550
265
230
FXGB-110D-3
110
3750
550
265
230
FXGB-110D-4
110
3950
550
265
230
FXGB-220D
220
6000
1000
425
395
FXGB-220S
220
6000
1000
425
395
  

This product is not less than the wire grip calculated tensile force of 5%, contact wire part adopts wear-resisting rubber damping semiconductor, the wear-resisting design components, expected service life: 20 years.

Four, installation requirements:

1, before installation, please read the installation instructions and graphical installation, check the product accessories and quantity, understanding the position of assembly parts, check the parts fit between.

2, the spacers must be vertical wire axially mounted, the upper part is inclined to the point of suspension, inclined to sag direction shall not exceed 80mm.

3, installation: fastening screws split 4 M10 accessories line clamp cover and the ear canal opening into the wire clamp mounting points, screw in fastening screw, pay attention to insulator umbrella skirt direction should be down.

4, adjust the line clamp, location, after installing the wire should keep the original state, which is in accordance with the requirements of second points, and then tighten the bolts, anti back pin insertion.

5, all the fastening bolt, connection components must be installed cotter pin.

Five, operation and maintenance:

Products factory prior to the GB/T19519-2004, GB/T20876.2-2007 and the related standard one by one test and sample test, in order to prevent the transport of damaged the user prior to installation and use should still be inspected visually; before use, should be kept properly, not subject to external pressure impact.

Composite interphase spacer is maintenance free equipment, but during operation should pay particular attention to its operation conditions, abnormal shall timely treatment, to sum up experience, in dancing and weather, should go to the site observation, the best video data, has analyzed.

Six, product packaging

1, composite interphase spacers 2

2, 1 copies of brochures

3, 1 copies of certificate

Seven, ordering:

1, when ordering please specify the product name, specifications, quantity, delivery date, there are no special requirements.

2, we not only offer the composite insulator various standard structure, according to the special requirements of users processing.

Schematic eight, product structure drawing:


 

1, the clamp cover 2, 3 M10 fastening bolts, ear groove clamp 4, wear sleeve
5, 6, M16 interphase insulation spacer bolt, nut, pin 7, damping rubber pad


 

Zhejiang ICP No. 0052142 2013 Copyright © 2013       CHINA SHANGYUAN ELECTRIC POWER SCIENCE & TECHINOLOGY CO.,LTD.       ChineseEnglish