● Use

FGNC-XD-type lightning Insulator Clamp string suitable for overhead distribution lines, the overhead insulated wire or bare wire is fixed on the sheet resistance to the corner bar or rod insulators, thereby fixing the overhead wires and taut; and overhead insulated wire or bare wires in the corner tension rods or rod fittings, thereby tightening the overhead wires and insulation resistance Zhang; provided with lightning ignition device, play the role of lightning.



●Outline
                    Due to global weather changes, often thunderstorms inclement weather, thunder and lightning weather more frequently, with the resulting grid failure accounted for 35.8% of the entire line failure, and in which the insulation off the sheet lightning rate of distribution lines accounted for 96.8 %, greatly affected the normal power line networks, causing losses to the national economy is also very serious, the current distribution lines lightning has caused considerable attention. 

This product is set to prevent breakage and prevent lightning damage insulator function, examine the electrical grounding function, self-locking wedge Tension clamp fixing and suspension functions lightning conductor pull holding insulator Clamp string. Its structure is reasonably new, simplified tension string and lightning protection devices, reducing the failure point, as one set of versatile, easy construction, energy efficient, attractive, long life, clip selection of interchangeable, easy procurement selection, and can be done throughout the insulated distribution function. Is a comprehensive upgrade of power lines and equipment replacement product.

● Specification

(1) Electrical Performance (1)电气性能

Model
Rated 
Voltage
(kV)
 
Rated 
Machinery 
Tensile 
Load 
(kN)
Frequency electric 
Arc current 
(Rms) 
kA
Minimum level 
Arc distance
(mm)
Least 
Nominal 
Creepage
Distance
(mm)
Lightning full 
Shock wave 
Power tolerance
Pressure (peak) 
Not less than 
(kV)
1min power frequency wet withstand voltage (RMS) of not less than(kV)
Remarks
FGNC10-240X
10
70
16.5
190
490
115
45
Ordinary
FGNC10-240XD
10
70
16.5
190
490
115
45
With ground
FGNC20-240X
20
70
16.5
380
980
175
72
Ordinary
FGNC20-240XD
20
70
16.5
380
980
175
72
With ground


(2)机械性能

10kV Model Specification
Insulated conductors (10kV) 
Wire section(mm)
20kV Model 
Specification
Insulated conductors (20kV) 
Wire section(mm)
Clamps grip 
Focus(kN)
Clamps damage load
(kN)
Remarks
FGNC10-50/95X
50/95
FGNC20-50/95X
50/95
8.9
14.2
Ordinary
FGNC10-50/95X
120/150
FGNC20-120/150X
120/150
13.6
23.1
FGNC10-50/95X
185/240
FGNC20-185/240X
185/240
22.5
36.2
FGNC10-50/95X
50/95
FGNC20-50/95XD
50/95
8.9
14.2
With ground
FGNC10-50/95X
120/150
FGNC20-120/150XD
120/150
13.6
23.1
FGNC10-50/95X
185/240
FGNC20-185/240XD
185/240
22.5
36.2
Zhejiang ICP No. 0052142 2013 Copyright © 2013       CHINA SHANGYUAN ELECTRIC POWER SCIENCE & TECHINOLOGY CO.,LTD.       ChineseEnglish